Connection

18

Functions assignable to P.Input1 to P.Input5 (input terminals)

Indication

Function

PLAY/PAUSE The same function as

HX

button on the

main unit

PLAY

The same function as

H

button on the

remote

PAUSE

The same function as

X

button on the

remote

STOP

The same function as

x

button

AMS +

The same function as

>

button on the

remote

AMS –

The same function as

.

button on the

remote

FF

The same function as

M

button

REW

The same function as

m

button

MARK

The same function as MARK button on the
remote

LOCATE

The same function as LOCATE button

EJECT

The same function as

A

EJECT button on

the main unit

Fader PLAY

Performs Fader Play (page 19)

1 Track PLAY
to 20 Track
PLAY

The same function as numeric buttons on
the remote

OFF

No operation

Functions assignable to P.Output1 to P.Output3 (output

terminals)

Indication

Function

PLAY

Grounding during playback on the player

PAUSE

Grounding during pause on the player

NO DISC

Grounding during no disc in the disc
compartment

OFF

Always floating

Do the procedure below to change the function of each
terminal.

1

Press the MENU/EXIT button while the player is
stopped.
“MENU Mode” appears in the display.

2

Rotate the AMS control until “Parallel” appears in
the display, and then push the control.
If “Parallel” is already set to “User,” skip this step
and step 3, and go to step 4.

3

Rotate the AMS control until “User” appears in the
display, and then push the control.

4

Rotate the AMS control until the terminal that you
want to assign function to (e.g., “P.Input1” or
“P.Output2”) appears in the display, and then push
the control.

5

Rotate the AMS control until the function that you
want to assign to the terminal that you selected
appears in the display, and then push the control.
To assign functions to more terminals, repeat steps
4 and 5.

6

Press the MENU/EXIT button to complete the
setting.

Notes

• When “Preset” is selected for “Parallel,” you cannot

select terminals or assign functions to them. To
enable the assigning of functions to terminals, first
select “User” for “Parallel.”

• Doing the procedure above with “Preset” selected for

“Parallel” allows you to check the factory setting for
each terminal.

Electrical specifications for the
PARALLEL connector

Input terminals

Input system

Make contact

Input ON voltage Less than 0.5 V
Input OFF voltage More than 3 V
Opening terminal voltage

5 V

Input pulse width More than 100 msec
Input standing voltage

–0.5 to +10 V

Output terminals

Output system

Open collector for NPN transistor

Remaining voltage at ON

Less than 0.5 V

Maximum current at ON

100 mA

Standing voltage

20 V