While recording – Sony MZ-RH10 User Manual

Page 72

Advertising
background image

72

While recording

Symptom

Cause/Remedy

“NOT ENOUGH
POWER TO REC”
appears and recording
cannot be done on a
1GB Hi-MD disc.

• Recording is not possible when using a 1GB Hi-MD disc even when

the battery level indication shows enough power remaining while the
recorder is stopped or playing. This is because of a mechanism that
disables recording when the remaining battery power is estimated by
the recorder to be insufficient due to the high power consumption
required for 1GB Hi-MD disc recording.
, Connect the AC power adaptor to the recorder or insert a fully

charged rechargeable battery or a new alkaline dry battery.

The remaining recording
time appears as “–00:00”
and recording cannot be
done, even though
2.0MB of free space is
displayed.

• This is a system limitation. 2.0MB is the capacity of the reserve

domain.

The recorder always
creates a new group
when recording.

• The group recording (“Group REC”) is set to “On”. (You cannot

overwrite tracks.)
, Set the group recording setting to “Off” (page 37).

The first few seconds of
a track cannot be
recorded.

• If you start recording before the x indication appears in the display,

data will not be recorded to the first few seconds of the first track.
, Wait until the x indication appears before you start recording.

Recording cannot be
done correctly.

• You tried to record in MD mode on this recorder.

, Only Hi-MD mode can be used to record directly on this

recorder without using a computer. To record in MD mode,
connect the recorder to a computer and use the supplied software
(pages 22 and 30).

• Audio sources may not be securely connected.

, Disconnect the audio sources once and connect them again

(pages 21 and 34).

• There is no digital signal from the portable CD player.

, When recording digitally from a portable CD player, use the AC

power adaptor and disable the anti-skip function (such as ESP)
on the CD player.

• The analog recording was made using a connecting cord with an

attenuator.
, Use a connecting cord without an attenuator.

• Recording level is too small to record (when adjusting the recording

level manually).
, Pause the recorder and adjust the recording level (page 35).

• The recorder is connected to the computer.

, Disconnect the recorder from the computer when recording.

• The power sources was disconnected or a power outage occurred

during recording.
, The recording result is not recorded on the disc. Make recording

again.