Connecting an external sync signal – Sony BRS-200 User Manual

Page 39

Advertising
background image

39

Connecting External Equipment

Chapt

er

3

Pre

par

at

ion
s

Connecting an External Sync Signal

To synchronize with the connected video devices, input the reference signal
from an external reference signal generator to the REF IN connector on the
switcher and to the external video sync signal input (EXT SYNC IN connector
for the BRC-series cameras).

If the connected device is not equipped with an external video sync signal
connector, set “FS” to “On” in the SETUP menu (page 53). The connected
device can be synchronized with the switcher using the built-in frame
synchronizer of the switcher.

1

2

3

4

PGM1

PGM2

AUX1

SDI OUT

SDI IN

AUX2

REF IN

REF OUT

RS-232C

~

AC IN

RS-422

DVI-I OUT

GENLOCK

VISCA

GPI I/O

PANEL

LAN(10/100)

REMOTE

IN1

IN2

OUT

T

W

A

B

HO

LD

l

s

L

j

G/

S

J

75-ohm coaxial cable

REF IN

First camera

Second camera

Third camera

75-ohm termination
switch: ON

75-ohm termination
switch: ON

Last camera

to EXT
SYNC
IN

to EXT
SYNC
IN

to EXT
SYNC
IN

to

GENLOCK

IN

Reference signal
generator

SG

Signal separator

75-ohm termination
switch: ON

75-ohm termination
switch: ON

75-ohm terminator

REF IN

Note