Configure the tacplus server – Siemens se5880 User Manual

Page 32

Advertising
background image

SIEMENS se5880 Ethernet Security Router
User’s Guide

Chapter 4 User Setup

User Management

SIEMENS

26

Configure the TacPlus Server

Tacplus allows access control and user authentication to be managed from a remote server.To configure the
Tacplus Server:

1. Click Configure Tacplus Server on the left navigation pane of the User Management page. This displays

the Tacplus Server Configuration page.

2. In Timeout, enter the number of seconds to between retry attempts when the Tacplus Server cannot be

reached.

3. In Retry, enter the number of times the Tacplus Server should be contacted before attempting to connect

to the secondary server.

4. In CACHE Timeout, enter the number of seconds that must pass before the user must be authenticated

again.

5. For Primary and optionally Secondary servers, provide the IP Address, Port, and Secret for accessing

the Radius Server. The Secret is used to authenticatn requests between servers.

Advertising