SpectraLink Corporation

Link WTS Installation and Operation

Part Number: 72-0075-01-C-W.doc

Page 21

Use only the provided Class II AC Adapter with output 24VDC, 1A.

!

!

For installations with more than one MCU, use an outlet strip with a built
in power switch. This allows the MCUs to be turned on and off together.

2. Plug the AC adapter into a 110VAC outlet or switch on the outlet strip to apply

power to the MCU.

Set Switch Interface Type

The following steps explain how to assign a switch interface type to the MCU. This
procedure

must be done in on each MCU

.

1. Power on the MCU with the Mode Switch in the

NORMAL

position.

Because the MCU does not have a switch type assigned, it will alarm (the Error
LED will flash along with Status LEDs 1,2,3,4 and 5). This should take less than
2 minutes.

2. Power off the MCU.

3. Move the Mode Switch to

ADMIN

and power on the MCU. Within 15 seconds,

Status LEDs 2 and 4 will light.

4. Press the

STEP

button three times.

Status LEDs 1, 2 and 4 must be lit. Line LEDs 1 through 8 (indicating an
unconfigured MCU) should also be lit.

If any other combination of Line LEDs is lit, then a switch type has already been
selected. Go to step 5 to pick the desired switch type.

5. Press the

DEL/ENTER

button to select the correct switch interface type. With

each press of the

DEL/ENTER

button, a different series of Line LEDs will be lit.

Continue to press

DEL/ENTER

until the correct Line LEDs are lit. Use the

following list to select the desired switch interface.