SpectraLink 150 M3 MCU User Manual

Page 33

Advertising
background image

SpectraLink Corporation

Link WTS Installation and Operation

Part Number: 72-0075-01-C-W.doc

Page 22

Switch Interface

Line LEDs

MCU Type

Notes

Analog

1

SCA

The SCA will only support Analog

Comdial

3

SCU

DEFINITY - 2 wire

1,4

SCU

DEFINITY - 4 wire

1,5

SCF

Executone

2,5

SCB

Fujitsu

2,4

SCU

Inter-Tel

2,3,4

SCU

Meridian

1,2

SCU

Merlin Legend

1,3

SCF

Mitel

1,2,3

SCX

The SCX will only support Mitel

NEC

1,2,4

SCU

Norstar

2

SCU

Panasonic

5

SCP

Siemens / Rolm

4

SCU

Toshiba

2,3

SCU-5XX

Unconfigured

1 through 8

6. Move the Mode Switch back to

NORMAL

.

7. The MCU will cycle through diagnostic testing. When the system is ready for

use, the error LED should be off, and the LED for the MCU Number (1-4) will be
lit. This should take less than two minutes.

If the LED for the MCU ID does not light, or if an MCU ID is duplicated, there is
most likely a problem with the IPC cabling. If the system displays an error refer
to 8.1 Troubleshoot Error Codes.

8. If you select a switch type that is not supported by the MCU type, the system will

alarm. The Error LED will flash along with Status LEDs 4 and 5. For example,
this alarm will display if you assign switch type NEC to an SCB-5XX –
Executone MCU.

If this alarm displays, use the table above to verify that your MCU type supports
the selected switch type. If you need to change the switch type, repeat steps 2
through 6.