Periodical recording mode setting section – Sony SNC-RZ30N User Manual

Page 37

Advertising
background image

Ad
minis

tra

ting t

he Camer

a

Recording Images in Memory — Image memory setting Page

37

Alarm

Select the alarm to link the Image memory function. If
the selected alarm is detected, a still image is captured
and recorded in the selected memory.
Sensor 1: External sensor connected to sensor input 1 of

the camera I/O port

Sensor 2: External sensor connected to sensor input 2 of

the camera I/O port

Sensor 3: External sensor connected to sensor input 3 of

the camera I/O port

Activity detection: The activity detection function built

in the camera.
To set the activity detection function, click Activity
detection
. The Activity detection setting page
appears (see page 40).

Available period

Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according

to the schedule selected in the Schedule No. menu
below.

Schedule No.

When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
check
. (See “Setting the Schedule — Schedule setting
Page” on page 40.)

Alarm buffer configuration

Click Alarm buffer to display the Alarm buffer setting
page.
For details, see “Setting the Alarm Buffer — Alarm
buffer setting Page” on page 38
.

Note

If an alarm occurs during the Alarm buffer processing,
that alarm is ignored.

Digest viewer

If you select On, an HTML file (.html) and a Java Script
file (.js) are added each time the selected alarm is
detected.
When you open the added HTML file using a general
browser, the digest viewer runs and you can view the
still pictures in the alarm buffer in sequence (quasi-
animation).
See “Operating the Digest Viewer” on page 30.

Periodical recording mode setting
Section

Interval time

Type the interval at which you want to record an image
periodically. You can set the hour (H), minutes (M) and
seconds (S) between 1 second and 24 hours (one day).

Available period

Select the period for which the periodical recording
mode is available.
Always: The periodical recording mode is available any

time.

Use scheduler: The periodical recording mode is

available according to the schedule selected in the
Schedule No. menu below.

Schedule No.

When Use scheduler is selected on the Available period
menu, select the schedule you want the periodical
recording mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
check
. (See “Setting the Schedule — Schedule setting
Page” on page 40.
)

Digest viewer

If you select On, an HTML file (.html) and a Java Script
file (.js) are added every 100 files.
When you open the added HTML file using a general
browser, the digest viewer runs and you can view the
still pictures in the alarm buffer in sequence (quasi-
animation).
See “Operating the Digest Viewer” on page 30.

Note

If the Suffix menu is set to None, you cannot select On.
When you want to use the digest viewer, set the Suffix
menu to Date/Time or Sequence number.

Back/OK

See “Buttons common to every setting page” on page
16.

Advertising