Maintenance and Cleaning

Turn off the projector, and unplug the AC power cord

from the AC outlet.
Turn over the projector and remove the air filter by

pulling the latches upward.

1
2

The air filter prevents dust from accumulating on the surface of the optical elements inside the projector. Should

the air filter become clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in a

buildup of internal heat and adversely affects the life of the projector. Clean the air filter by following the steps

below.

Gently clean the filter by using a brush or blower.

3

Reinstall the filter into the projector properly.

4

CAUTION

Do not operate the projector with the air filter

removed. Dust may accumulate on the optical

elements degrading picture quality. Do not put

anything into the air intake vents. Otherwise it may

result in malfunction of the projector.

RECOMMENDATION

We recommend avoiding dusty/smoky environments when you operate the projector. Usage in these

environments may cause poor image quality.

When you use the projector under dusty or smoky conditions, dust may accumulate on the lens, LCD panels, or

optical elements inside the projector degrading the quality of a projected image.

When the symptoms above are noticed, contact your authorized dealer or service station for proper cleaning.

Note:

• When cleaning the air filter, protect the

infrared remote receiver with a soft cloth to

avoid damaging it.

• If the filter is heavily clogged and unable to

clean, replace it with a new one. Consult

your dealer for details.

Replacement Filter Part No.: 610 335 4057

Air filter
Pull up and remove.

Cleaning the Air Filter

Clean up the dust on the projector and around the air

vents.

5

WARNING: Do not wash the filter with water and

any other liquid matter. Otherwise the filter may

be damaged.

Be sure to reset the Filter counter after cleaning or replacing the filter.

Press the MENU button to display the On-Screen

Menu. Use the Point

7 8

buttons to move the red

frame pointer to the Setting Menu icon.

Use the Point

ed

buttons to move the red frame

pointer to Filter counter and then press the SELECT

button. A dialog box appears showing the total

accumulated time of the filter use, a timer setting

option, and the reset option. Select Reset and the

“Filter counter Reset?” appears. Select [Yes] to

continue.

1

2

Resetting the Filter Counter

Filter counter

Select Reset and
the “Filter counter
Reset?” appears.

Select [Yes],
then another
confirmation box
appears.

Select [Yes] again
to reset the Filter
counter.

Another confirmation dialog box appears, select [Yes]

to reset the Filter counter.

3

Reset the filter counter in the Setting Menu. See

“Resetting the Filter Counter” below.