Sharp SF-1120 User Manual

Page 111

Advertising
background image

(2) User simulation

Simulation procedure

State

Paper jam/Maintenance/

Mini maintenance/

Paper supply/Toner supply/

Warning LED

Copy

quantity

display

Copy

button

LED

1. Press the tray selection

key for 5 sec or more.

User simulation input is allowed.

Blink

OFF

2. Enter the simulation code

No. with the10-key pad.

Selection of simulation code No.

Blink

ON

3. Press the COPY button.

Determination of simulation code

Blink

ON

4. Enter the selection code

No. with the 10-key pad.

Selection of simulation code menu

Blink

ON

5. Press the COPY button.

Determination of simulation code menu

Blink

OFF

6. Press the tray selection

key.

Escape from user simulation.

OFF

Returns to
the copy
quantity
display.

When this key is pressed during selection of user
simulation, the mode returns to 1 (User simulation is
allowed.).

*

Press the clear key.

(Use this key in case of erroneous input)

Blink

OFF

After setting the program, when this key is pressed, the
next program input is allowed.

(

:

Blink)

1

1

1

2

1

2

1

(3) User simulation code table

Program

Sim.

code

Selection code:

Set content

Factory

setting

Auto clear passing time
setting

[1]

[0]: Cancel
[1]: 30 sec
[2]: 60 sec
[3]: 90 sec
[4]: 120 sec

2

Pre-heat mode setting and
passing time setting

[2]

[0]: Cancel
[1]: 1 min
[2]: 15 min
[3]: 60 min
[4]: 120 min

2

Auto power shut off mode
setting and passing time
setting

[3]

[0]: Cancel
[1]: 5min
[2]: 15 min
[3]: 30 min
[4]: 60 min
[5]: 120 min

2

Program

Sim.

code

Selection code:

Set content

Factory

setting

Auto pre-heat control mode
setting and cancel

[4]

[0]: Cancel
[1]: Setting

0

Auto document feeder
manual document feed mode
setting

[5]

[0]: Cancel
[1]: Setting

0

Sorter take-out mode

[7]

[0]: Cancel
[1]: Setting

1

Auto paper selection

[8]

[0]: Cancel
[1]: Setting

1

Auto tray selection

[9]

[0]: Cancel
[1]: Setting

1

(4) Department counter setting content (Set with user program P10

P15)

Function name

Setting content

Factory setting

P10

Department counter

setting/cancel

The department counter is set or canceled.

Cancel

P11

Department No. registration

The department number is registered. Up to 20 departments can be
registered.

No setting

P12

Department No. change

The registered department number is changed.

No change allowed.

P13

Department No. delete

The registered department numbers are deleted.
One department number or all the department numbers can be deleted.

No delete allowed.

P14

Copy quantity display (Total)

The copy quantity of each department is displayed.
The count is made up to 50,000. After that, the count starts from 0 again.

No display allowed.

P15

Copy quantity delete (Total delete)

The counted copy quantity is deleted.
One department or all the department can be deleted.

No display allowed.

(*

)

(

*

): Because of no registration of department No. at all.

8 – 21

Advertising
This manual is related to the following products: