Trouble code

Sub code

Content

Condition

F1

00

Sorter communication error

•

An error occurred in communication between the sorter and
the main unit.

02

Transport motor trouble

•

During rotation of the transport motor, the rotation pulse is
not sensed for 0.5 sec or more.

04

Bin upper limit/lower limit trouble

•

When shifting the bins, the upper limit or the lower limit is
erroneously sensed.

05

Bin home sensor trouble

•

When initializing the bins, the bin home sensor is not
sensed within 1 sec.

06

Bin motor trouble

•

During rotation of the bin motor, the rotation pulse is not
sensed for 0.5 sec or more.

14

Take-out sensor trouble

•

When the take-out sensor A/D input value is 3V or more.

16

Grasping motor trouble

•

During rotation of the grasping motor, the rotation pulse is
not sensed for 0.05 sec.

F2

31

Image density sensor trouble

•

When the light emitting quantity of the image density
sensor is increased to the maximum level, the input value
does not reach 3.75V.

•

When the light emitting quantity of the image density
sensor is decreased to the minimum level, the input value
does not fall below 4.5V.

•

During execution of the grid voltage correction, the element
level is 3V or lower.

32

Drum mark sensor trouble

•

During one and a quarter rotations of the drum, the drum
mark is not sensed (the sensor input does not become
HIGH).

•

The drum mark sensor input level is not in the specified
range.

33

Grid voltage correction trouble (Limit
over)

•

When obtaining the grid voltage correction value, the result
of the patch voltage is not in the range of 200

∼

650V.

35

Grid voltage correction trouble

•

When obtaining the grid voltage correction value, the patch
voltage is not in the range of 200

∼

650V.

•

The grid voltage correction cannot be performed properly.
(The correction value cannot be obtained.)

37

Drum mark sensor gain adjustment
trouble

•

Though the drum mark sensor light emitting quantity is
increased to 1.45V, the sensor input level does not become
LOW.

EE

EU

Auto developer adjustment under
toner detection

•

After completion of the auto developer adjustment
(simulation 25-2), the toner density sensor input voltage is
over the specified range. (Under toner)

EL

Auto developer adjustment over
toner detection

•

After completion of the auto developer adjustment
(simulation 25-2), the toner density sensor input voltage is
under the specified range. (Over toner)

CC

Original detection trouble

•

When the original detection sensor judgement level setting
(SIM 41-2) is performed, the difference between the original
presence level and the original empty level is too small.