Sharp SF-1120 User Manual

Page 77

Advertising
background image

2-2. Note for adjustments

1. Only the exposure balance adjustment, the blank lamp adjust-

ment, and the copy lead edge adjustment can be performed
individually.
For the other adjustments, follow the flowchart below.

1. Mechanical reference position adjustment (without copying)

2. Adjustment while
copying

A. No. 2/3 mirror unit parallelism adjustment

Vertical skew copy adjustment --- Manual adjustment

B. Check the following preset values according to the lens focus rank.

Lens reference position adjustment --- SIM 48-01

No. 4/5 mirror reference position adjustment --- Manual adjustment

1. Image distortion,

center shift check

2. Normal (x 1.00),

zooming (x 2.00)

resolution (focus)

check

3. Normal copy

magnification ratio

(vertical, horizontal)

check

4. Exposure balance,

blank lamp position,

lead edge variation

check

END

Image distortion

Vertical skew copy adjustment
Horizontal skew copy adjustment

Center shift:

Lens center shift adjustment

Resolution (focus) adjustment

Normal: Adjust with the No. 4/5
mirror adjustment screw.

Zooming: Adjust with the zooming
cam.

Copy magnification ratio adjustment

Vertical copy magnification ratio
adjustment

Horizontal copy magnification
ratio adjustment

Exposure balance adjustment
Blank lamp position adjustment

Copy lead edge adjustment
(Including the void area
adjustment.)

YES

NO

YES

NO

YES

NO

YES

NO

7 – 3

Advertising
This manual is related to the following products: