Plug & play, Damper wire, Power saving function – Sony GDM-W900 User Manual

Page 17: Power saving operation

Advertising
background image

17

EN

F

D

ES

I

J

Power
consump-
tion

200 W

140 W

15 W

8 W

0 W

Plug & Play

This monitor complies with the DDC

1, DDC2B and

DDC2AB which are the Display Data Channel (DDC)
standards of VESA.
When a DDC1 host system is connected, the monitor
synchronizes with the V. CLK in accordance with the VESA
standards and outputs the EDID (Extended Display
Identification Data) to the data line.
When a DDC2B or DDC2AB host system is connected, the
monitor automatically switches to each communication.

DDC

is a trademark of Video Electronics Standard Association.

Damper Wire

Using a white background, very thin horizontal lines on the
screen are visible as shown below. These lines are damper
wires.
The Trinitron tube has a vertically striped Aperture Grill
inside. The Aperture Grille allows more light to pass
through to the screen giving the Trinitron CRT more color
and brightness.
These damper wires are attached to the Aperture Grille to
prevent vibration of the Aperture Grille wire so that the
screen image is constantly stable.

Power
consumption
state

Normal
operation

Standby
(1st state)

Suspend
(2nd state)

Active-off
(3rd state)

Power-off

POWER
SAVING
indicator

Off

Orange on

Orange on

Orange on

Off

1

2

3

4

5

Power Saving
Function

This monitor is capable of three states of reduced power

consumption. By sensing the absence of video signals and
one or both sync signals coming from the host computer, it
will reduce power consumption as follows.

Power saving operation

The H-sync is not present.
/

The unit goes into standby state.

The V-sync is not present.
/

The unit goes into suspend state.

Both the H-sync and V-sync are not present.
/

The unit goes into active-off state.

The monitor requires a video card or screen saver software

which switches off one or both sync signals to activate the
power saving function.

Caution

If no video signal is input to the monitor, or if the INPUT

switch is set to the connector to which no signal is input
when you turn on the monitor, the input signal warning
indicator (page 18) appears. After 30 seconds, the Power
Saving function automatically puts the monitor into the
Active-off state and the POWER SAVING indicator lights
up. Once the horizontal and vertical syncs are sensed, the
monitor will automatically return to its Normal operation
state.

Recovery
time

Approx.
3 sec.

Approx.
3 sec.

Approx.
10 sec.

u (power)
indicator

Green on

Green on

Green on

Off

Off

Damper wire

Advertising