11. function of status out connector, 12. unleaded solder – Sony PFV-L10 User Manual
Page 16
1-10 (E)
PFV-L10
1-11. Function of STATUS OUT Connector
1-12. Unleaded Solder
8
1
15
9
1-11. Function of STATUS OUT Connector
The PFV-L10 output the following status with the STATUS OUT connector.
<External view>
Pin No.
Signal
Location
Status
L
H
1
DIAG 1
SLOT 1
Normal operation or No board
Board: Error
2
DIAG 2
SLOT 2
Normal operation or No board
Board: Error
3
DIAG 3
SLOT 3
Normal operation or No board
Board: Error
4
DIAG 4
SLOT 4
Normal operation or No board
Board: Error
5
DIAG 5
SLOT 5
Normal operation or No board
Board: Error
6
DIAG 6
SLOT 6
Normal operation or No board
Board: Error
7
DIAG 7
SLOT 7
Normal operation or No board
Board: Error
8
DIAG 8
SLOT 8
Normal operation or No board
Board: Error
9
DIAG 9
SLOT 9
Normal operation or No board
Board: Error
10
DIAG PS B
POWER B
Normal operation
Power : OFF or
Temperature : Too high
11
DIAG PS A
POWER A
Normal operation
Power : OFF or
Temperature : Too high
12
FAN STOP
FAN
Normal operation
Stop
13
OVER LOAD
POWER A, B
Normal operation
Load current: 13 A or more
(Load current: less than 13 A)
14
DIAG 10
SLOT 10
Normal operation or No board
Board: Error
15
GND
_
_
_
1-12. Unleaded Solder
Boards requiring use of unleaded solder are printed with a
lead free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come
printed with the lead free mark due to their particular size.)
: LEAD FREE MARK
m
. Be sure to use the unleaded solder for the printed circuit
board printed with the lead free mark.
. The unleaded solder melts at a temperature about 40 dC
higher than the ordinary solder, therefore, it is recom-
mended to use the soldering iron having a temperature
regulator.
. The ordinary soldering iron can be used but the iron tip
has to be applied to the solder joint for a slightly longer
time. The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful.