4. status indications – Sony PFV-L10 User Manual

Page 9

Advertising
background image

1-3 (E)

PFV-L10

1-4. Status Indications

The status indicators A and B on the front panel indicate the present condition of the PFV-L10.

Power Supply Unit

Indicator

Condition

Indicator A

Indicator B

One unit

Lights in green

_

Normal operation

Blinks in red

_

.

The cooling fan has stopped rotating.

.

The total current for the plug-in boards has
exceeded 13 A.

.

The temperature inside the power supply unit A
has risen over a specified level.

Two units

Lights in green

Lights in green

Normal operation

Blinks in red

Lights in green

Power supply unit A

.

The power switch is set to OFF.

.

The AC cable has come off.

. +

5 V voltage is not output.

.

The temperature inside the power supply unit has
risen over a specified level.

Power supply unit B: Normal operation

Lights in green

Blinks in red

Power supply unit A: Normal operation
Power supply unit B

.

The power switch is set to OFF.

.

The AC cable has come off.

. +

5 V voltage is not output.

.

The temperature inside the power supply unit has
risen over a specified level.

Blinks in red

Blinks in red

.

The cooling fan has stopped rotating.

.

The total current for the plug-in boards has
exceeded 13 A.

.

The temperature in the power supply block (power
supply units A and B) has risen over a specified level.

1-4. Status Indications

Power supply unit A

Status indicator A

Status indicator B

Power supply unit B

Advertising