P31003-E8400-A100-3-7620
Service Manual

5-5

Nur für den internen Gebrauch

Option Adapters and Ports

optiPoint 500 acoustic adapter

●

Ringing, alerting, and key tones are switched to the basic speaker (and not to the external
speaker port).

●

You can use the volume keys on the telephone to adjust the volume level of both the inter-
nal and external speakers.
You can also use the volume control on the external amplifier to adjust the volume of the
external speaker.

Pin assignments, Desk Microphone and External Speaker: MW 8/8

External Speaker:

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

Pin 7

Pin 8

+U

GND

NF

Sens

LS_SENS

LSP

NC

DGND

Internal resistance:

0 ohms; 10

µF

Level (with PCM -20dBm):

-4.8 dBm (at volume level 8; 0.775 V = 0 dBm)

Sense lead to GND:

Int. speaker deactivated, active for ringer only

1

2 3 4 5 6 7 8

RJ45

Y cable MW8/8

for connecting
speaker and mi-
crophone

Floating contact
(MW6/6)

Headset MW8/8