IP Adapter
Nur für den internen Gebrauch
P31003-E8400-A100-3-7620
7-20
Service Manual
Administration Via the Web Browser
18. Click “Diagnostic” and test whether the line connection configured can be set up.
Diagnostics
The tests on this page do not require assistance from a local user.
Return to
Administration Home
Invoke tests
Select which tests to invoke:
Ping
RAM test
ROM test
19.24.34.198
-- IP address:
Invoke
Reset
Test results
Ping:
Last run at 17:40, 25 Feb 1999
Result:
successful;
response received after 28mS
Address pinged: 19.24,.34.198
RAM test:
Last run at 17:40, 25 Feb 1999
Result:
failed
ROM test:
Last run at 9:33, 4 Jan 1999
Result:
passed
This page will be reloaded with the updated
test results after the tests have been invoked.