Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Switch Host Connection

This section contains the following example configurations:

■

“Dual Hosts With Two Switches and Two Controller Units” on page 46

■

“Dual Hosts With Two Switches and Eight Controller Units” on page 48

Dual Hosts With Two Switches and Two
Controller Units

FIGURE 4-12

shows two application hosts connected through FC-AL cables to two

switches and two Sun StorEdge T3+ arrays. This multi-initiator configuration can be
used for footprint and I/O throughput.

Note –

This configuration is not a recommended for RAS functionality because the

controller is a single point of failure.

Evaluate the following limitations before proceeding with this configuration:

■

Avoid the risk caused by any array or data path single point of failure using host-
based mirroring software such as VERITAS Volume Manager or Solaris Volume
Manager.

■

When configuring more than a single array to share a single FC-AL loop, as with
a hub, array target addresses need to be set to unique values.

Each array needs to be assigned a unique target address using the port set
command. These target addresses can be any number between 1 and 125. At the
factory, the array target addresses are set starting with target address 1 for the
bottom array and continuing to the top array. Use the port list command to
verify that all arrays have a unique target address. Refer to Appendix A of the Sun
StorEdge T3 and T3+ Array Administrator’s Guide
for further details.

The following two parameters must be set on the master controller unit, as follows:

■

cache mode = auto

■

cache mirroring = auto

Note –

For information on setting these parameters, refer to the Sun StorEdge T3 and

T3+ Array Administrator’s Guide.