COLOR IR CAMERA

COLOR IR CAMERA

User’s Manual

User’s Manual

17

16

The recommended adaptor specification for SIR-4150N/P is DC 12V/4A.
Please check the standard power requirement before connecting to power.

Connecting to Power

• As shown in the table above, voltage decreases as the wire gets longer.

Therefore use of an excessively long adaptor output line for connection to
the camera may affect the performance of the camera.

Standard voltage for camera operation : DC 12V±10%
There may be some deviation in voltage drop depending on the type of wire and the manufacturer.

When the resistance value of copper wire is at [20°C(68°F)]

Copper wire size(AWG)

#24(0.22mm

2

)

#22(0.33mm

2

)

#20(0.52mm

2

)

#18(0.83mm

2

)

Resistance value(Ω/m)

0.078

0.050

0.030

0.018

Voltage drop(V/m)

0.028

0.018

0.011

0.006

• Please must be used adaptor that meets the standard requirement.
• Please connect the power after installation.

Note

Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC

Using a RS-485 converter, It connects to RS-485 CONTROL TERMINAL outside
camera and serial cable

EX) SERIAL PORT OF THE PC(COM1) — SERIAL CABLE -- RS-485 CONVERTER

-- RS-485 CONTROL TERMINAL

(2)The case which it controls from the DVR or System Controller

It connects the RS-485 CONTROL TERMINAL in the connection terminal of 485
control boards which are connected with the DVR or System Controller.

Connecting to RS-485 CONTROL TERMINAL

• When you construct external control systems for a camera control, please use to

the PELCO-D PROTOCOL.

• When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer

skin inside the RS-485 CONTROL TERMINAL.

Notes

CONTROL TERMINAL SPEC
WHITE (TRX+)

RS-485+

BLACK (TRX-)

RS-485-

485 CONTROL BOARD CONNECTION TERMINAL

RS-485 CONTROL TERMINAL

(+)CONNECTION TERMINAL

WHITE (TRX+)

(-)CONNECTION TERMINAL

BLACK (TRX-)

RS-485 communication control