Timing of replacing the lamp, Replacing the lamp, Timing of replacing the lamp replacing the lamp – Sim2 Multimedia DIGITAL D60 User Manual

Page 44

Advertising
background image

44

Additional information

Timing of replacing the lamp

When the Lamp indicator lights up red or a message appears suggesting it is time to replace

the lamp, please install a new lamp or consult your dealer. An old lamp may cause a

malfunction in the projector and in some instances the lamp may explode.
The Lamp indicator light and Temperature warning light will light up if the lamp becomes too

hot. Turn the power off and let the projector cool for 45 minutes. If the Lamp or Temp
indicator still lights up after turning the power back on, please contact your dealer. See

"Indicators" on page 46

for details.

The following Lamp warning displays will remind you to change the lamp.

Replacing the lamp

To reduce the risk of electrical shock, always turn the projector off and disconnect the power cord before
changing the lamp.

To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replacing the
lamp.

To reduce the risk of injuries to fingers and damage to internal components, use caution when removing
lamp glass that has shattered into sharp pieces.

To reduce the risk of injuries to fingers and/or compromising image quality by touching the lens, do not
touch the empty lamp compartment when the lamp is removed.

Status

Message

The lamp has been in operation for 2500 hours. Install a new

lamp for optimal performance. If the projector is normally run

with Whisper selected (See

"Getting to know the lamp hour" on

page 43

), you may continue to operate the projector until the

2950 hour lamp warning appears.

Press ENTER to dismiss the message.

The lamp has been in operation for 2950 hours.

A new lamp

should be fitted to avoid the inconvenience when the projector
runs out of lamp time.

The lamp has been in operation for 3000 hours. It is strongly

recommended that you replace the lamp at this age. The lamp

is a consumable item. The lamp brightness diminishes with use.

This is normal lamp behavior. You can replace the lamp

whenever you notice that the brightness level has significantly

diminished. If the lamp is not replaced beforehand, it should be

replaced after 3000 hours usage.
Press ENTER to dismiss the message.

The lamp MUST be replaced before the projector will operate

normally.
Press ENTER to dismiss the message.

OK

Order Replacement Lamp

Lamp > 2500 Hours

Notice

OK

Replacement Lamp Soon

Lamp > 2950 Hours

Notice

OK

Replacement Lamp Now

Lamp > 3000 Hours

Lamp-usage time exceeded

Notice

Out of Lamp Usage Time

Replace lamp (refer to User Manual)
Then reset lamp timer

OK

WARNING

Advertising