English, Volt 1 2, Battery (mxc/exc) – KTM 250 EXC RACING User Manual

Page 40: Charging the battery

Advertising
background image

ENGLISH

39

Battery (MXC/EXC)

The battery is located under the seat and is maintenance-free.
It is not necessary to check the electrolyte level or to refill water. Simply
keep the battery poles clean and slightly grease them with an acid-free
grease if necessary.
Removing the battery:
First disconnect the negative and then the positive pole of the battery.
Remove the filter box cover and unhitch both rubber bands

1

.

Remove battery.Install the battery with the terminals facing the front (see
illustration), connecting the negative terminal post to the battery last.

ƽ

WARNING

ƽ

– I

F ELECTROLYTE

(

SULPHURIC ACID

)

LEAKS FROM THE BATTERY

,

PROCEED WITH GREAT

CARE

. T

HE ELECTROLYTE CAN CAUSE SEVERE BURNS

.

– I

N THE CASE OF SKIN CONTACT RINSE THOROUGHLY WITH WATER

.

– I

N THE CASE OF CONTACT WITH THE EYES

,

THOROUGHLY RINSE EYES WITH WATER

FOR AT LEAST

15

MINUTES

. I

MMEDIATELY CONSULT A DOCTOR

.

– T

HE BATTERY IS A CLOSED MODEL BUT CAN NEVERTHELESS EMIT EXPLOSIVE GASES

.

A

VOID SPARKS AND OPEN FIRE NEAR THE BATTERY

.

– D

EFECTIVE BATTERIES MUST BE STORED OUT OF THE REACH OF CHILDREN

. E

NSURE

PROPER DISPOSAL OF DISCARDED BATTERIES

.

!

CAUTION

!

– T

O AVOID DAMAGE

,

DO NOT REMOVE THE LOCKING BAR

2

!

– N

EVER DISCONNECT THE BATTERY WHILE THE ENGINE IS RUNNING

. T

HIS WILL

DESTROY THE RECTIFIER

-

REGULATOR

.

– T

HE BATTERY MUST BE INSTALLED WITH THE TERMINALS FACING THE FRONT

(

AS

SHOWN IN THE ILLUSTRATION

),

OTHERWISE ELECTROLYTE CAN ESCAPE

.

BATTERY STORAGE:
When preparing the motorcycle for a longer period of standstill, remove the
battery and recharge it. Storage temperature: 0 - 35°C (30 - 95°F). Do not
expose to direct sunlight.

Charging the battery

Remove the battery and check the charging level. Use a voltmeter to
measure the voltage between the battery poles (off-load voltage).
Accurate results can only be obtained if the battery has neither been charged
nor discharged during a period of 30 minutes preceding the measuring.

If the battery is empty, it can be recharged for a maximum period of
10 hours at 0.5 A and a maximum of 14.4 V.

!

CAUTION

!

– T

O AVOID DAMAGE

,

DO NOT REMOVE THE LOCKING BAR

.

– A

LWAYS CONNECT THE BATTERY TO THE CHARGING UNIT BEFORE TURNING THE

CHARGING UNIT ON

.

– W

HEN RECHARGING THE BATTERY IN CLOSED ROOMS THERE IS SUFFICIENT VENTI

-

LATION

. E

XPLOSIVE GASES ARE RELEASED DURING THE BATTERY CHARGING PROCESS

.

– C

HARGING TIME AND CHARGING VOLTAGE SHOULD NOT EXCEED THE STATED VALUES

.

O

THERWISE ELECTROLYTE WILL BE RELEASED THROUGH THE SAFETY VALVES

.

– A

VOID QUICK CHARGING IF POSSIBLE

.

off load voltage

charging level

charging time

charging voltage

Volt

%

0,5 A

>12,7

100

––

~12,5

75

4 h

max.

~12,2

50

7 h

14,4 V

~12,0

25

11 h

~11,8

0

14 h

VOLT

1

2

Advertising