Mixer setup, Mixer run-in – Kuhn Rikon 3000 SERIES 3030 User Manual

Page 17

Advertising
background image

17

3000STOPR005810R082503

KUHN KNIGHT INC.

1501 West 7th Ave. Brodhead, WI 53520-0167

701 Cherry Ave. Greeley, Co. 80632

MIXER RUN-IN

1. Check for proper assembly, adjustment, and lubrication. Check to see that there is adequate oil in the oil bath,

check to be sure all bolts and set screws are tight and the drive belts are at the proper tension. Review Operating

Safety Precautions and Lubrication Instructions before operating the mixer.

2. Be sure all shields are properly in place.

3. Check for and remove any foreign objects in the mixer hopper and discharge opening.

4. Check to see that drain plugs are installed and that the door is closed.

5. Be sure no one is inside the mixer.

6. Test run the mixer.

a. Make sure mixer is empty, then start the mixer.

b. Run for at least five minutes.

c. Raise and lower the door several times.

d. Turn off mixer and lock out power.

e. Check the mixer drive components to be sure they are not abnormally hot. Refer to

Inspection and Adjustment section for proper alignment and tension settings.

If any of these items are not running as indicated, immediately repair or contact your service

representative. Always refer to Operating Safety Precautions before operating or servicing the mixer.

IMPORTANT! READ BEFORE OPERATING MIXER.

IT IS THE RESPONSIBILITY OF THE OWNER TO MAKE SURE THE MIXER IS SET

UP PROPERLY. THE FOLLOWING RECOMMENDATIONS SHOULD BE HELPFUL

MIXER SETUP

Advertising