Trouble shooting – Kuhn Rikon 3000 SERIES 3030 User Manual

Page 33

Advertising
background image

33

3000STOPR005810R082503

KUHN KNIGHT INC.

1501 West 7th Ave. Brodhead, WI 53520-0167

701 Cherry Ave. Greeley, Co. 80632

PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH

CAUSE

SOLUTION

PROBLEM: HYDRAULIC DOOR SYSTEM OPERATES ERRATICALLY

COMPONENTS STICKING OR BINDING

Check for hydraulic oil contamination, dirt, or gummy deposits. If

dirt is found, search and repair the source. Check for worn or

bent parts. Check oil level in hydraulic system.

INADEQUATE FLOW OR PRESSURE FROM HYDRAULIC SYSTEM.

Check fluid and fill to proper level.

OIL IS LEAKING PAST SEALS IN CYLINDERS OR VALVES

Install seal kits to repair worn seals. See parts listing for part

numbers.

CAUSE

SOLUTION

INSPECT SHIELD FOR LOOSENESS

Carefully tighten wing nuts or adjust locking fasteners that hold

shield in place, hand tighten only. Check for foreign material

between the foam gasket and shield.

DAMAGED OR LOOSE GASKET MATERIAL AROUND ENCLOSURE SHIELD

Remove shield and check gasket material for proper adhesion to

the mating panel of mixer. If gasket adhesive has come loose

from front panel, replace gasket.

PROBLEM: SCALE HANGS UP, LOAD CELL ONLY

LOAD CELL NOT VERTICAL

Load cell should be vertical, if not first inspect check arm

assembly and or pin check assembly. Second adjust by

loosening top load cell mount in a no load condition, adjust load

cell to a vertical position and tighten fasteners.

PIN CHECK OUT OF ADJUSTMENT

Remove pin check assembly, test scale, if scale operates

properly clean or repair pin check assembly. Also see “INSPEC-

TIONS AND ADJUSTMENTS SECTION”

SWING ARM NOT LUBRICATED

lubricate check arm (should rotate on sockets without great

effort). Also see “INSPECTIONS AND ADJUSTMENTS SECTION”

CAUSE

SOLUTION

PROBLEM: SCALE WEIGHS VERY HEAVY OR VERY LIGHT, WEIGH BAR ONLY

IMPROPER CALIBRATION

CALIBRATE SCALE refer to scale operators manual for informa-

tion

DAMAGED CABLE ON ONE OR MORE LOAD CELLS

Inspect cables and repair or replace as necessary.

CAUSE

SOLUTION

TROUBLE SHOOTING

Advertising