Section 7 retractable starter – Kohler COMMAND CH18-745 User Manual

Page 112

Advertising
background image

7.1

Section 7

Retractable Starter

7

Section 7

Retractable Starter

WARNING: Spring Under Tension!

Retractable starters contain a powerful, recoil spring that is under tension. Always wear safety goggles when
servicing retractable starters and carefully follow instructions in this section for relieving spring tension.

CH18-745

To Remove Starter

1. Remove the five hex. flange screws securing the

starter to the blower housing.

2. Remove the starter.

To Install Starter

1. Install the retractable starter onto the blower

housing, leaving the five hex. flange screws slightly
loose.

2. Pull the starter handle out until the pawls engage

in the drive cup. Hold the handle in this position
and tighten the screws securely.

Rope Replacement

The rope can be replaced without complete starter
disassembly.

1. Remove the starter from the blower housing.

2. Pull the rope out approximately 12 in. and tie a

temporary (slip) knot in it to keep it from retracting
into the starter. See Figure 7-2.

Handle with
Rope Retainer

Drive Cup

Starter Housing

Rope

Pawl Springs

Pawls

Pawl Retainer

Plain Washer

Center Screw

Brake Spring

Brake Washer

Pulley

Spring and
Keeper

Hex.
Flange
Screws

Figure 7-1. Retractable Starter - Exploded View.

Advertising