8.30

Section 8
Electrical System and Components

Figure 8-44. Removing Thru Bolts.

5. Remove the commutator end plate assembly,

containing the brush holder, brushes, springs, and
locking caps. Remove the thrust washer from
inside the commutator end. See Figure 8-45.

Figure 8-45. Removing Commutator End Plate
Assembly.

6. Remove the frame from the armature and drive

end cap. See Figure 8-46.

Figure 8-48. Armature and Lever Removed.

10. Push the stop collar down to expose the retaining

ring. See Figure 8-49.

Figure 8-46. Starter Frame Removed.

7. Remove the drive lever pivot bushing and backing

plate from the end cap. See Figure 8-47.

Figure 8-47.

8. Take out the drive lever and pull the armature out

of the drive end cap. See Figure 8-48.

9. Remove the thrust washer from the armature

shaft. See Figure 8-48.