9.9

Section 9

Disassembly

9

Figure 9-34. Removing Fasteners Holding Baffle
and Breather Cover.

2. Remove both inner baffles. See Figure 9-35.

Figure 9-35. Removing Inner Baffles.

3. Remove the two remaining screws holding the

breather cover to the crankcase. See Figure 9-35.

4. Pry under the protruding edge of the breather

cover with a screwdriver to break the RTV or
gasket seal. See Figure 9-36. Do not pry on the
sealing surfaces as it could cause damage
resulting in leaks. Most engines use a formed
gasket rather than RTV sealant.

Figure 9-32. Removing Metal Grass Screen.

7. Remove the lower blower housing screw and

washer securing the rectifier-regulator ground
lead or grounding strap.

8. Remove the remaining hex. flange screws and

detach the blower housing. See Figure 9-33.

9. Disconnect the plug from the key switch in the

blower housing if engine is so equipped.

Figure 9-33. Removing Blower Housing.

Remove Inner Baffles and Breather Cover

The inner (valley) baffles are attached at one corner
using the same fasteners as the breather cover. See
Figure 9-34.

1. Remove the two hex. flange screws securing the

inner baffles.