C-12

H4: Parity

Parameter value

Meaning

0

None

1

Odd

2

Even

3

Ignore

The factory setting is “None” (0 on the status printout).

H5: Protocol logic

Parameter value

Meaning

0

Combination of 1 and 3 below

1

DTR/DSR, positive logic

2

DTR/DSR, negative logic

3

XON/XOFF

4

ETX/ACK

5

XON/XOFF recognized only as protocol

The factory setting is 0.

H6: Buffer nearly-full threshold

This is a percentage from 0 to 99. The factory setting is 90.

H7: Buffer nearly-empty threshold

This is a percentage from 0 to 99. The factory setting is 70.

The factory settings of the buffer nearly-full and nearly-empty thresholds (H6 and H7) are subject to

change without notification.