16

58

VS-3 VOICE SYNTHESIZER UNIT

CAUTION: SWITCH OFF THE POWER AND UNPLUG THE DC
POWER CABLE BEFORE BEGINNING INSTALLATION.

1 Remove the bottom case (8 screws).

2 Hold the VS-3 unit with the component side facing

inward, and insert the VS-3 connector into the
transceiver CN16 connector.

3 Replace the bottom case (8 screws).

Note: The VR8 allows you to adjust the volume for voice
announcement. Use only when the volume level is too low or too
high.

YK-88C-1/ YK-88CN-1/ YK-88SN-1
FILTERS

CAUTION: SWITCH OFF THE POWER AND UNPLUG THE DC
POWER CABLE BEFORE BEGINNING INSTALLATION.

1 Remove the 2 screws from the bottom cover of the

transceiver.

2 Remove the bottom cover.

14 INSTALLING OPTIONS

3 Remove the 2 screws from the OPTION FILTER

section of the transceiver PC board.

4 Align the pins of the transceiver CN8 and CN9

connectors with the two connectors on the filter.

Take care to properly align the pins.

5 While holding the filter, carefully push down until the

filter snaps into place.

6 Re-install the 2 screws that you removed in step 3.

7 Replace the bottom cover (2 screws).

Note: After installing the filter, be sure to select the appropriate
setting in Menu No. 46; otherwise the filter will not function.

VR8

Bottom cover

CN9

CN8

Filter

CN16

Component side

VS-3