Kohler Command CV730 User Manual

Page 148

Advertising
background image

8.32

Section 8
Electrical System and Components

Figure 8-48. Removing Thru Bolts.

5. Remove the commutator end plate assembly,

containing the brush holder, brushes, springs,
and locking caps. Remove the thrust washer from
inside the commutator end. See Figure 8-49.

Figure 8-49. Removing Commutator End Plate
Assembly.

6. Remove the frame from the armature and drive

end cap. See Figure 8-50.

Figure 8-52. Armature and Lever Removed.

10. Push the stop collar down to expose the retaining

ring. See Figure 8-53.

Figure 8-50. Starter Frame Removed.

7. Remove the drive lever pivot bushing and

backing plate from the end cap. See Figure 8-51.

Figure 8-51.

8. Take out the drive lever and pull the armature out

of the drive end cap. See Figure 8-52.

9. Remove the thrust washer from the armature

shaft. See Figure 8-52.

Advertising
This manual is related to the following products: