9.6

Section 9
Disassembly

Figure 9-18. Removing Control Bracket.

Figure 9-19. Removing Control Bracket and Air
Cleaner Bracket (Some Models).

2. Disconnect the spring from the governor lever;

note hole locations for reassembly.

3. Remove the choke linkage from the choke

actuator lever and carburetor.

Remove External Governor Controls

1. Loosen the hex flange nut and remove the

governor lever from the cross shaft. See Figure
9-20. Leave the lever attached to the throttle
linkage.

Figure 9-20. Removing Governor Lever.

Remove Carburetor

WARNING: Explosive Fuel!

Gasoline may be present in the carburetor and fuel system.
Gasoline is extremely flammable, and its vapors can explode
if ignited. Keep sparks and other sources of ignition away
from the engine.

1. Disconnect the fuel shut-off solenoid lead if so

equipped.

Control Bracket

Air Cleaner Brackets
(Some Models)

Control Bracket

Governor Lever

Figure 9-21. Removing Fuel Solenoid and Ground
Leads (Two-Barrel Model Pictured).

2. Remove the carburetor mounting nuts. See Figure

9-21.

Fuel Solenoid
Lead

Ground Lead