8.33

8

Section 8

Electrical System and Components

Figure 8-54. Removing Retaining Ring.

12. Remove the drive pinion assembly from the

armature.

13. Clean the parts as required.

NOTE: Do not soak the armature or use solvent

when cleaning. Wipe clean using a soft cloth,
or use compressed air.

Figure 8-53. Retaining Ring Detail.

11. Remove the retainer from the armature shaft.

Save the stop collar.

NOTE: Do not reuse the old retainer.

Lever

Solenoid

CE Frame

Bolt

Ring
Stop

Drive

Armature

Washer

Screw

Plunger

Spring

Plate

Collar

Tube

Screw

Plug

Frame & Field

Brush Holder
Nut

Figure 8-55. Delco-Remy Starter.