Konica Minolta CF5001 User Manual

Page 123

Advertising
background image

OTHER CONTROLS

CF5001 Ver.1.0 Sep. 2003

2-70

II UNIT EXPLANA

TION

15.2 Parts that operate only when the power switch is turned on

15.2.1

Parts that operate when the reset switch is turned on

When the reset switch (SW1) turns on, AC power is supplied to the DC power unit /1 (DCPS1), AC drive

board (ACDB) and the DC power unit /4: optional (DCPS4).

As a result, DCPS1 supplies 5 VDC to the overall control board (OACB) to monitor it with the main switch

(SW2).

The ACDB turns ON the HTR relay (RL3) in the board and provides 24 VAC to each heater via the trans-

former/main body (TRNS1) and the transformer/LCT (TRNS2).

15.2.2

Parts that operate when the main switch is turned on

When the main switch (SW2) is turned on, the overall control board (OACB) detects this condition and

sends a control signal to the DC power unit /1 (DCPS1) and the AC drive board (ACDB).

As a result, DCPS1 supplies 3.5 VDC, 5 VDC, 12 VDC and 24 VDC to all the boards and optional devices.

The ACDB turns ON the HTR relay (RL3) in the board and provides 24 VAC to each heater via the trans-

former/main body (TRNS1) and the transformer/LCT (TRNS2).

8050ma2039

SW1

SW2

5VDC

5VDC

24VDC

REMOTE

5VDC

3.3VDC

5VDC

12VDC

5VDC

12VDC
24VDC

5VDC

12VDC

DCPS1

ACDB

RL2

RL3

RL1

OACB

PRCB

TSDB

CVDB

DCPS2

HTR1,2

TRNS1

TRNS2

Fixing unit

DF-319

(OPTION)

DCPS4

(OPTION)

FS-115/215

(OPTION)

LT-211

(OPTION)

IPB

OB1

Advertising