Konica Minolta CF5001 User Manual

Page 62

Advertising
background image

CF5001 Ver.1.0 Sep. 2003

SCANNER

2-9

II UNIT EXPLANA

TION

1.2.6

AE control

The CCD sensor installed on the A/D converter board (ADB) reads the copy density during the AE scan, it

performs the process responsive to the read density on the overall control board (OACB), and then it

selects the most favorable

γ correction curve. The CPU on the image processing board (IPB) performs the

selection.

A.

AE/ACS sampling range

The AE/ACS sampling range is identical to the read range in both the platen mode and the DF mode.

1.2.7

Image processing

A. AOC (automatic offset control)

With the circuit in the CCD sensor, AOC automatically adjusts the analog offset voltage from the sensor to

be the lower limit of the A/D converter.

B.

AGC (automatic gain control)

GC automatically controls the level of the analog amplification of the CCD sensor output at the shading

white correction to be the higher limit for the A/D converter.

C.

Shading correction

(1) Types of the shading correction

White correction

Black correction

(2) Execution timing

At the main switch (SW2) ON

At the start of scan job

[1]

10 mm

[2]

AE/ACS sampling range

8050ma2054

[1]

[2]

[1]

[1]

[1]

Advertising