Konica Minolta CF5001 User Manual

Page 61

Advertising
background image

SCANNER

CF5001 Ver.1.0 Sep. 2003

2-8

II UNIT EXPLANA

TION

1.2.5

APS control

The APS control is performed in the printer control board (PRCB) with signals read by the APS sensor /S

(PS3), the APS sensor /L (PS4), and the CCD sensor when the platen cover or RADF is opened/closed.

The signal is sent via the scanner drive board (SCDB) and the overall control board (OACB) (see the AFR-

20 Service manual for more detailed information on the APS control by AFR-20).

A.

APS operation

The APS sensor /S (PS3) and the APS sensor /L (PS4) detect the original size in the sub-scan direction

and the CCD sensor detects the original size in the main scan direction.

B.

Relationship between each of the sensors and the original size

C.

APS detection timing (platen mode)

The original size in the main scan direction is detected twice. The larger size is regarded as the original

size.

Original size

CCD sensor

(Length of detection: mm)

PS3

(ON/OFF)

PS4

(ON/OFF)

Smallest

102

OFF

OFF

B5R

182

ON

OFF

B5

257

OFF

OFF

B4

257

ON

ON

A4R

210

ON

OFF

A4

297

OFF

OFF

A3

297

ON

ON

8.5 x 11R

215.9

ON

OFF

8.5 x 11

279.4

OFF

OFF

8.5 x 14

215.9

ON

ON

11 x 17

279.4

ON

ON

[1]

1st original size detection

(main scan direction, sub-scan direction)

[2]

2nd original size detection

(main scan direction)

[1]

[2]

8050ma2009

APS sensor /S (PS3)

APS sensor /L (PS4)

Exposure lamp (L1)

APS timing sensor (PS2)

DF reset read switch (RS1)

Advertising