Sat operation, Scan – Kathrein MSK 33 User Manual

Page 27

Advertising
background image

Sat Operation

27

SCAN

With the function SCAN, satellites can be searched for, whose transponder fre-
quencies are not known. Here, the frequency range of 920 to 2150 is continuously
scanned for the receiving signals. If the receiving signals are available, the recep-
tion level is displayed on the screen as a bar diagram. Four measurement ranges
with the dynamic of each 40 dB are available for the bargraph display. The meas-
urement range is automatically preselected.

Bargraph
display

Level range

Comment

I

30-70 dBµV

Automatic range change at 70 dBµV

II

50-90 dBµV

Auto. range change at 50 and 90 dBµV

III

70-110 dBµV

Auto. range change at 70 and 110 dBµV

IV

90-130 dBµV

Automatic range change at 90 dBµV

The level can be controlled with an acoustic signal. The frequency of the acoustic
signal varies in proportion with the receiving signal level. The volume of the acous-
tic signal can be changed.


The screen shows the bargraph display, which changes in
proportion with the input signal.

The field SCAN lights up yellow, as soon as the softkey is pressed. The entire Sat
frequency range is now scanned. By pressing the button once more, the process is
stopped and the softkey display changes to “scan off.“



Calling up menu LNB-CONTROL

In this menu, all LNB parameters can be set, for example, remote power feeding
voltage H/V, 22-kHz-, DiSEqC-, V-SEC signal, UFOµ DiSEqC as well as LO fre-
quency.

Switch-over of ANALOG digit. DVBS

Calling up the menu SAT MEASURE

In this menu, all Sat receiving parameters for the reception of digital or analogue
signals can be set and the measurements can be carried out. Calls up the MPEG-
Decoders for digit. DVB-S.


LNB

CONTROL

digit.
DVBS >

SAT

MEASURE

analog

>

Advertising