Sat Operation

30

DiSEqC menu

With the MSK 33, DiSEqC commands can be sent (TX) and received (RX). The
code words –framing, address, command, data- are displayed on the screen in the
upper RX display field for received DiSEqC commands and in the lower TX display
field for transmitted DiSEqC commands. Two additional display fields are available
for the explanation of the DiSEqC commands. The DiSEqC code words can be en-
tered-in and edited in hexcode.

RX assessment

After pressing the appropriate key, the
field lights up yellow for ca. 3 seconds.
During this time, DiSEqC commands can
be received and assessed. The display of
the received DiSEqC command appears
in the RC display field.

Transmitting and receiving a
DiSEqC command (TX + RX)

The set DiSEqC com-
mand in the TV display
field is transmitted after
pressing this button.

Afterwards, the MSK 33 switches to re-
ception, in order to assess a sent back
DiSEqC command, and the RX field lights
up yellow (only for DiSEqC systems). For
DiSEqC 2.0 systems, confirmation will not
be sent back.

Sending a DiSEqC command (TX)

After pressing this button, the set DiSEqC command in the TX display field is
transmitted.

(In the COPY menu, various pre-programmed DiSEqC commands can be called up
under „recall 85…90“)

Entry of the hex numbers

Calls up a submenu for entering the DiSEqC command.


RX display field

The received DiSEqC command is represented in the RX dis-
play field.


If no DiSEqC command is received, the display shown on the
left appears.