Tv operation, Analogue menu – Kathrein MSK 33 User Manual

Page 45

Advertising
background image

TV Operation

45

Analogue menu

Calls up the TV menu


Selecting the standard

With this softkey, the
following standards can
be selected: B/G, D/K, I,
L, M, M – jap. (Japan)
and N. Refer to the audio
carrier table.

In this menu, the channel setting can be
changed using the cursor buttons, ◄►. In
the RP menu, the receiving frequency can
be changed in this manner.


Audio carrier table for TV reception

The given audio carrier frequencies are based on the video audio carrier

spacing

Standard

Audio carrier 1

(sc1)

Audio carrier

(sc 2)

Audio carrier (1 +2

sc)

NICAM

(nicam)

B/G

5.50 MHz

5.74 MHz

sc 1: 5.50 MHz
sc 2: 5.74 MHz

5.85 MHz

L

6.50 MHz (AM)

5.85 MHz

D/K

6.50 MHz

6.26 MHz

sc 1: 6.50 MHz
sc 2: 6.26 MHz

5.85 MHz

I

6.00 MHz

6.552 MHz

M

4.50 MHz

4.72 MHz

sc 1: 4.50 MHz
sc 2: 4.72 MHz

M (Japan)

4.50 MHz

N 4.50

MHz

Selecting the audio carriers

By pressing the button, the MSK 33 can be set to the following reception types:

• Audio carrier 1 (sc1)
• Audio carrier 2 (sc2)
• Stereo (sc1 + sc2)
• NICAM (nicam)

Level-dependent acoustic signal

In the function, „level beep,“ the acoustic signal is generated, whose pitch is pro-
portionate to the received signal level. With this, it is possible to optimally align the
receiving antenna to a transmitter.

Carrying out measurements

By pressing the button, the MSK 33 is set to analogue reception and measures the
following values:

- Audio carrier spacing of TT1 (sc1) and TT2 (sc2)
- Nicam audio carrier spacing (if available)
– Nicam bit error rate (BER)

A