1 general considerations, 2 location, 3 vehicle-floor mounting – Kohler 13ERG User Manual

Page 13

Advertising
background image

TP-6335

9/04

Location and Mounting 3

Section 2 Location and Mounting

2.1 General Considerations

Consider the following items concerning the generator
set and Section 2.2 for the proposed location.

1. Select a generator set having adequate capacity to

handle the electrical load.

2. Design the fuel system to prevent fuel starvation of

the main or generator set engine.

3. Ensure that the exhaust system meets all safety

requirements after installation.

4. Ensure compatibility of all electrical systems

(battery, load, and remote switch) with the vehicle’s
electrical systems.

2.2 Location

Note: This generator set is not designed for installation

in a compartment or enclosure.

Before making final plans for locating the generator set,
ensure the following:

1. The location has sufficient room to maintain

required minimum clearances.

2. The location provides enough air flow to allow

required cooling and combustion.

3. The location can support the generator set weight.

4. The location provides ample room for routine

service of the generator set’s engine, controller,
cooling system, and fuel system components.

See the current generator set specification sheet or
Section 7 of this manual for generator set dimensions
and weights.

For angular operating limits, consult the operation
manual.

2.3 Vehicle-Floor Mounting

Install the Kohler mobile generator set on an open
vehicle’s floor or truck bed. Follow the guidelines below.
Contact an authorized Kohler service distributor/dealer
with your specific application questions.

Minimum clearance. Allow clearance for vibration and
cooling during operation.

Minimum clearance for

vibration (top, front, rear, and sides) is 38 mm (1 1/2 in.).
Keep the radiator end unobstructed for proper air flow.

Additional clearance. Generator set service requires
more clearance than 38 mm (1 1/2 in.).

Design the

mounting location to allow for sufficient room to easily
remove the generator set to perform major service.

Securely fasten the generator set to avoid unwanted
movement from vibration and road shock. Attach the
generator set vibromounts directly to the vehicle’s
frame. See Figure 2-1 for vibromount installation.

1. Lock nut
2. Flat washer (7/16 x 1)
3. Generator set frame
4. Vibromount
5. Vehicle frame
6. Flat washer (13/32 x 2)
7. Screw (3/8--16 x 2--1/4)

ADV6816-

1

2

3

4

5

6

Purple (2)

Engine end

White (2)

Generator end

Color

Mounting Location

7

Vibromount

Top View

Vibromount

Side View

Figure 2-1

Vibromount Installation

Advertising
This manual is related to the following products: