Kohler 13ERG User Manual

Page 43

Advertising
background image

TP-6335

9/04

Reconnection/Adjustments 33

Parameter

Setting

Definition

Unit’s system voltage
and frequency

Uu01

Single phase, 60 Hz, 120/240 VAC

Unit configuration

Uc02

Mobile generator set

Engine type

Ec03

10/13/15ERG

Engine data input types
(N

i

i k

)

Ed00

All digital inputs

g

p

yp

(No magnetic pick-up)

Ed01

Digital: Low coolant level and low oil pressure
Analog: Low coolant temperature

Ed02

Digital: Low coolant level and low coolant temperature
Analog: Low oil pressure

Ed03

Digital: Low coolant level
Analog: Low coolant temperature and low oil pressure

Ed08

Digital: Low coolant temperature and low oil pressure
Analog: Low coolant level

Ed09

Digital: Low oil pressure
Analog: Low coolant level and low coolant temperature

Ed10

Digital: Low coolant temperature
Analog: Low coolant level and low oil pressure

Ed11

All analog inputs

Battery voltage

Bt12

Battery voltage 12 VDC

Communications

Cn00

No CAN communications

Cn01

SAE J1939 (Used for ADC remote digital gauge)

Cn02

Future CANbus

Figure 8-8

Controller Parameters