14 Electrical System

TP-6335

9/04

Note: Transfer switch. Use a triple-pole, double-throw

transfer switch rated for the calculated load of the
vehicle to transfer the load from one source to the
other. Install a ground-fault circuit interrupter in
the wiring system to protect all branch circuits.

Note: AC load circuit protection. Protect the AC load

circuit of the generator set against overloading or
short circuiting with a circuit breaker(s).

Note: For standby service connect output of the

generator to a suitably rated transfer switch in
accordance with the Canadian Electrical Code,
Part 1.

120-V

Outside

Power

AC Vehicle Circuit

Ground Fault
Circuit Protection

L1

L2

Gen.
Set

N

N

N

L0

120 Volt

240-V

Outside

Power

AC Vehicle Circuit

Ground Fault
Circuit Protection

L1

L2

Gen.
Set

N

N

N

L0

240 Volt

Figure 6-1

Transfer Switch Connections,
3-Wire AC Circuit