Sat measurement, Level measurement – Kathrein MSK 24 User Manual

Page 20

Advertising
background image

Sat measurement

20

Level Measurement

Once you have set a frequency, the level is measured automatically and
displayed in dBìV or dBmV (depending on the basic configuration) on the
LC display. The input level can be measured in the range of 30 dBìV to
120 dBìV (-30 dBmV to 60dBmV).

LC display:

Frequency: 1508MHz

Mode: SAT

Measured level: 86.5dBìV

Level Overflow and Underflow

The LC display indicates unterflow at a level <30 dBìV, e.g.

Frequency: 1508 MHz

Mode: SAT

Level: underflow

The LC display indicates overflow at a level >120 dBìV.

The following information appears in the display:

Frequency: 1508 MHz

Mode: SAT

Level: overflow

Note

Levels of DVB-S signals can be measured in the digital reception setting
only.

only

FR:1508.0MHz SAT
LEV: 86.5dBuV

FR:1508.0MHz SAT
LEV:
__._dBuV

FR:1508.0MHz SAT
LEV:

dBuV

+

Advertising