Sat measurement – Kathrein MSK 24 User Manual

Page 27

Advertising
background image

Sat measurement

27

Example

You want to test the Kathrein matrix EXR 22. The command set for the
matrix EXR 22 is E0 00 24 (LNB High) and E0 00 20 (LNB Low).

Call up DiSEqC:

Press buttons [2ndF] [SAT-CTRL]

Press button [3] to call up the DiSEqC control.

SAT-CTRL menu

You can now enter the data bits for each code word using the buttons [0]
to [9] and [./S]. Send the control command by pressing [ENTER]. The >
symbol indicates that the control command has been sent.

DiSEqC menu

The command set to control the Kathrein matrix EXR 22 has been
entered and sent.

DiSEqC menu

Note

You can find the DiSEqC command sets for the Kathrein matrices
EXR 20, EXR 22 and the 9xx series in the Technical Appendix.

Overview of commands in Framing Byte

HEX
Byte

Description

E0

Command from master, single transmission

E1

Command from master, repetitive transmission

E2

Command from master, answer expected, first transmission

E3

Command from master, answer expected, repeated
transmission

E4

Answer from slave, "OK", no error detected

E5

Answer from slave, command not supported by slave

E6

Answer from slave, parity error detected

E7

Answer from slave, command not detected

SAT-CTRL LNB=1
V-SEC=2 DiSEqC=3

DiSEqC-Framing

DiSEqC-COMMAND
E0 00 24 >

0

+

л