28

Overview of commands in Address Byte

Hex byte

Description

00

All equipment

10

Every LNB, matrix or SMATV

11

LNB

12

LNB with loop-through

14

Matrix (switcher)

15

Matrix (switcher) with loop-through

18

SMATV

20

Every polarizer

21

Maximum rotation (full skew) with lineal polarization

22

Set polarizer in steps

30

Every positioner

31

Polar / Azimuth positioner

32

Elevation positioner

33

Combined positioner

34

LNB positioner

40

Installation help

41

Help to set signal strength

60

Reserved for allocated addresses

70

"Intelligent slave interface" for "Proprietary multi-
master bus"

71

Interface for users and checked head stations

Fx

OEM expansion