2. In the available fields, enter or modify the following information:

Connect Protocol

Protocol

From the drop-down menu, select TCP.

Connect Mode: Passive Connection

Accept Incoming

Select Yes to accept incoming connections. The default
setting is Yes.

Password Required

Determines whether a password is required for an
incoming passive connection. This field is not available
when a password is set for Telnet mode. The default
setting is No.

Password

If Password Required was set to Yes, enter the password
for passive connections.

Connect Mode: Active Connection

Active Connect

Select None (default) to disable Active Connect.
Otherwise, indicate the connection type from the drop-
down list:

With Any Character:

Attempts to connect when any

character is received from the serial port.

With Active Mdm Ctrl In:

Accepts external

connection requests only when the
modem_control_in

input is asserted.

With Start Character:

Attempts to connect when it

receives a specific start character from the serial
port. The default start character is carriage return.

Manual Connection:

Attempts to connect when

directed by a command string received from the
serial port.

Auto Start:

Automatically connects to the remote IP

address and port after booting up.

Start Character

If Active Connect is set to With Start Character, enter the
start character in this field. The default setting is 0D.

Modem Mode

Indicates the on-screen response type when in Modem
Mode (if Modem Mode is enabled). The default setting is
None.

Endpoint Configuration

Local Port

Enter the local port number.

Auto increment for
active connect

Select to auto-increment the local port number for new
outgoing connections. The range of auto-incremented
port numbers is 50,000 to 59,999 and loops back to the
beginning when the maximum range is reached. Disabled