4: Configuration Using Web-Manager

UDS1100 User Guide

33

Remote Port

Enter the remote port number.

Remote Host

Enter the IP address of the remote device.

Common Options

Telnet Com Port Cntrl

This field is available for configuration only when Active
Connect

is set to None. Select Enable to permit Telnet

communication to the UDS1100 unit. The Telnet Com Port
Cntrl

feature is used in conjunction with the Com Port

Redirector (CPR) utility. (See the CPR online Help for details.)

Terminal Name

This field is available for configuration only when Telnet Com
Port Cntrl i

s set to Enable.


Use the terminal name for the Telnet terminal type. Enter only
one name. When this option is enabled, the unit also reacts to
the end of record (EOR) and binary options, which can be
used for applications such as terminal emulation to IBM hosts.

Connect Response

A single character is transmitted to the serial port when there
is a change in connection state. The default setting is None.

Use Hostlist

If this option is set to True, the device server scrolls through
the host list until it connects to a device listed in the host list
table. Once it connects, the unit stops trying to connect to any
others. If this connection fails, the unit continues to scroll
through the table until it connects to another IP in the host list.

The host list is disabled for Manual Mode and for Modem
Mode. The unit will not accept a data connection from a
remote device when the host list option is enabled.

LED

Select Blink for the status LEDs to blink upon connection or
None

for no LED output. The default setting is Blink.

Disconnect Mode

On Mdm_Ctrl_In Drop

Set to Yes for the network connection to or from the serial port
to disconnect (drop) when Modem Control In transitions from
an asserted state to not asserted state. The default setting is
No

.

Hard Disconnect

When set to Yes, the TCP connection closes even if the
remote site does not acknowledge the disconnect request.

Check EOT (Ctrl-D)

Select Yes to drop the connection when Ctrl-D or Hex 04 is
detected. Both Telnet Com Port Cntrl and Check EOT
(Ctrl+ D)

must be enabled for Disconnect with EOT to

function properly. Ctrl+D is only detected going from the serial
port to the network. The default setting is No.

Inactivity Timeout

Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter 00:00.

3. When you are finished, click the OK button.