Setup mode: advanced settings, Expert settings (option 5), Tcp keepalive time in seconds – Lantronix UDS1100 User Manual

Page 55: Figure 8-1. expert settings, Setup mode: advanced, Settings

Advertising
background image

UDS1100 User Guide

55

8

8

:

:

S

S

e

e

t

t

u

u

p

p

M

M

o

o

d

d

e

e

:

:

A

A

d

d

v

v

a

a

n

n

c

c

e

e

d

d

S

S

e

e

t

t

t

t

i

i

n

n

g

g

s

s

Expert Settings (Option 5)

Note:

You can change these settings using Telnet or serial connections only,

not on the Web-Manager.

Caution:

Changing the expert settings can drastically affect the

performance and access to the product. These settings should only be
changed by an experienced network administrator.

Figure 8-1. Expert Settings

The default settings are listed below:

TCP Keepalive time in s
(1s – 65s; 0s=disable)

45

ARP Cache timeout in s
(1s – 600s)

600

Disable Monitor Mode @
bootup

Enabled

HTTP Port Number
(1-65535)

80

MTU Size (512 – 1400)

0 (resulting in an operational value of 1400)

Enable alternate MAC

Disabled (OEM use only)

Ethernet connection type

0 (resulting in auto-negotiation)

TCP Keepalive time in seconds

This option allows you to change how many seconds the unit waits during a silent
connection before attempting to see if the currently connected network device is still
on the network. If the unit gets no response, it drops that connection. The default
setting is 45.

TCP Keepalive time in s (1s – 65s; 0s=disable): (45)? _