Test is okay. go to step 6, Troubleshooting & repair, Continued) – Lincoln Electric SQUARE WAVE TIG 255 SVM100-A User Manual

Page 66: Arc start trigger circuit test

Advertising
background image

SQUARE WAVE TIG 255

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-25

TROUBLESHOOTING & REPAIR

ARC START TRIGGER CIRCUIT TEST

(continued)

PROTECTION/SNUBBER

L9255

J10

J11

J12

J13

J14

J15

10J12

3J12

3J13

11J13

6.

Test the resistance from 11J13 on the
projection/ snubber board to pin “D” on
the six pin amphenol receptacle. (Lead
#311). Also check resistance from 3J13
on the projection/snubber board to pin
“E” on the six pin amphenol receptacle.
(Lead #303).

FIGURE F.9 - PROTECTION/SNUBBER BOARD TEST POINTS.

FIGURE F.10 - ARC START TRIGGER CIRCUIT.

A. If zero ohms resistance is shown

test is okay. Proceed to projection/
snubber board test.

B. If resistance of any value is shown,

check wires and connections.

Advertising