Lennox International Inc. o23v User Manual

Page 24

Advertising
background image

Page 24

1

2

3

TJERNLUND HORIZONTAL VENTING SYSTEM (SIDESHOT) OPERATION SEQUENCE

:

1.

When 1K2 closes, 120VAC is routed through the relay/timer, electronic ignitor (A73), and the limit switch.

2.

The relay/timer energizes the venter motor.

3.

After the venter motor establishes a draft, the N.O. fan proving switch closes completing the circuit to the burner motor.

1

2

3

FIELD CONTROL HORIZONTAL VENTING SYSTEM OPERATION SEQUENCE

:

1.

When 1K2 closes, 120VAC is routed through the relay.

2.

The relay energizes the venter motor.

3.

After the venter motor establishes a draft, the N.O. fan proving switch closes, completing the circuit to the burner motor and electronic ignitor (A73).