Lennox Hearth MODEL MONTAGE 32FS User Manual

Page 11

Advertising
background image

11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Vent Termination Locations

A = Clearance above grade, veranda, porch, deck, or balcony (min.

12”/30cm)

B = Clearance to window or door that may be opened (min. 12”/30cm

above - 48”/1.2m below and to the side)

C = Clearance to permanently closed window *(min. 12”/30cm)

D = Vertical clearance to ventilated soffit located above the terminal

within a horizontal distance of *(min. 24”/60cm) from the center-

line of the terminal (min. 22”/55cm) check with local code.

E = Clearance to unventilated soffit *(min. 12”/30cm)

F = Clearance to outside corner *(min. 12”/30cm)

G = Clearance to inside corner *(min. 12”/30cm)

H = Not to be installed above a meter/regulator assembly within *(min.

36”/90cm) horizontally from the centerline of the regulator.

J = Clearance to service regulator vent outlet *(min. 72”/1.8m)

K = Clearance to non-mechanical air supply inlet to building or the

combustion air inlet to any other appliance *(min. 48”/1.2m)

L = Clearance to a mechanical air supply inlet *(min. 120”/3.1m)

M = **Clearance above paved sidewalk or a paved driveway located on

public property *(min. 84”/2.1m)

N = ***Clearance under veranda, porch, deck, or balcony (min.

12”/30cm)

Note:

*

Local codes or regulations may require different clearances.

** A vent shall not terminate directly above a sidewalk or paved

driveway which is located between two single family dwellings

and serves both dwellings.

*** Only permitted if veranda, porch, deck, or balcony is fully open on

a minimum of two sides beneath the floor.

Vent Terminal
Area Where Terminal Is Not Permitted

(From Eave)

Vertical Terminal

Vertical Terminal

Fixed Closed

Able To Open

A

A

B

B

B

B

C

D

E

F

G

H

J

K

L

M

N

24”

(610mm)

B

Air Supply Inlet

24”

(610mm)

Figure 9

E. The distance from the bottom of termination to grade is 12” (305 mm)

minimum. This is conditional upon plants and nature of grade surface: Be

careful to choose a location for the vent termination which does not expose

people or shrubs to high heat from the exhaust gases. The exhaust gases

are not hot enough to ignite grass, plants and shrubs located in the vicinity

of the termination although they should be a minimum of 3 feet (.92 m)

away. The grade surface under the termination must not be a lawn.

F. Since sparks may escape from the exhaust pipe of any stove, use

caution when positioning the vent pipe. Refer to pipe manufacturer’s

instructions when installing and terminating the exhaust. The vent pipe

should be horizontal and never run the pipe in a downward direction

(recommend a 1/4” [7 mm] rise per foot horizontal).

B. Not less than 4 feet (1.2 m) below, 4 feet (1.2 m) horizontally from or

1 foot (3.1 m) above any gravity air inlet (door, window, etc.) which

flue gases could reenter the dwelling.

C. Not less than 2 feet (.6 m) from combustible materials such as an

adjacent buildings, fences, protruding parts of the structure, roof

overhang, plants and shrubs, etc. and not less than 7 feet (2.1 m)

above grade when located adjacent to the public sidewalks (access).

The final termination of the exhaust system must be configured so that

flue gases do not jeopardize the safety of people passing by, overheat

combustible portions of nearby structures or enter the dwelling.

D. Not less than 3 feet (.92 m) below an eave (maximum overhang of 3

feet (.92 m) or any construction that projects more than 2” (51 mm)

from the plane of the wall.