Important – Lennox Hearth MODEL MONTAGE 32FS User Manual

Page 5

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

5

Up to * 6” (153 mm)

6”

(153 mm)

min.

6”

(153 mm)

min.

6” (153 mm)

min.

Figure 1 -

Floor Protection Requirements

* Notes: When installed at clearances less than 6”, the floor

protection is only required to extend to the wall. Refer to

Page 4 for chimney/venting floor protection requirements and

recommendations.

Rear

Front

Top View

Floor Protector

Standard residential or manufactured home installation. These appliances

require the following minimum clearances to combustibles:

Figure 2

Combustible

Combustible

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

NE PAS ENLEVER CETTE ÉTIQUETTE DÉGAGEMENT MINIMUM POUR LES

MATÉRIAUX COMBUSTIBLES
Freestanding Stove Installation / Installation Du Poêle Autonome
Manufactured (Mobile) Home Or Residential Installation / Installation Résiden-

tielle Ou Dans Une Maison réfabriquée (Mobile)
A - Side wall to unit

4” (10 mm)

B - Back wall to unit

” (51 mm)

C - Side wall to unit Corner

1” (5 mm)

D - Max. Depth of Alcove

u

4” (610 mm)

E - Flue to Wall

v

3 " (76mm)

u

Minimum Alcove Measurements - Height 48” (10 mm) x Width 31”

(788 mm) x Maximum Depth 4” (610 mm)

v

See vent manufacturer to verify clearances

Table 1

Combustible

Rear Wall or Alcove - Clearance to Combustibles

Figure 3

Corner - Clearance to Combustibles

B

A

*E

D

A

E*

C

C

Combustible

Combustible

IMPORTANT

• Minimum clearances specified may not allow

for ease of operation and maintenance (please

take this in to account when planning the instal-

lation). If installed to the minimum clearances,

removal of the appliance may be necessary for

servicing.

• Recommended clearance zone from the front

of the appliance to combustibles is 4 feet mini-

mum.

• Clearances to combustibles for the appliance

can only be reduced by means approved by the

regulatory authority.

CLEARANCES - Montage™ 3FS

*Note: Refer to pipe Manufacturer's installation

instructions for minimum pipe clearances.

*Note: Refer to pipe Manufacturer's installation

instructions for minimum pipe clearances.

Advertising