Technical Data

TPS1200

179

8.6

PowerSearch PS

Range

Measurements at the vertical limits of the fan or under unfavourable atmospheric
conditions may reduce the maximum range. (*aligned to the instrument optimal)

Shortest
measure distance

Searching

Characteristics

Reflector

Range PS
[m]

[ft]

Standard prism

200

650

360° prism

200*

650*

Mini prism

100

330

360° prism:

5 m

Typical search time:

<10 s

Default search area:

Hz: 400 gon, V: 40 gon

Definable search windows: Yes

Principle:

Digital signal processing

Type:

Infrared laser class 1